GDVLF-80S High Voltage VLF AC Hipot Test Set for Cable Insulation Testing
Withstand voltage test is an essential preventive test for electrical equipment. It is divided into two parts: AC and DC withstand voltage test. AC test can be further divided into power frequency, variable frequency and 0.1Hz very low frequency test, among which the last one is highly recommended by IEC, due to its remarkable advantages.
-
GDTF Variable Frequency AC Resonant Test System
GDTF Series AC Resonant Test System For Cables are composed of frequency/voltage adjustment power supply, excitation transformer, reactors and capacitive divider.The power frequency can be adjustable, which make the reactor and tested capacitor resonance.
-
GDZJ-10S Turn-to-turn Surge Tester
GDZJ-10S is used to test turn-to-turn insulation strength of single phase motor, 3-phase motor, Micro motor, Special motor, electrical motor, transformer (including switching mode power supply transformer), relay and winding electrical equipment.
-
GDYD-63A Versatile AC/DC Hipot Test Set for Comprehensive Electrical Testing
GDYD-63A AC/DC Hipot Test Set is composed of automatic control unit and AC oil testing transformer (HV unit) which output AC voltage smoothly. Meanwhile, it has many monitoring and protection functions. When the short circuit rod of testing transformer is taken out, the output is DC voltage.
-
Hipot Test Set With Automatic Control
AC hi-pot testing is the effective and direct way to test insulation strength for electrical equipment, apparatus or machines. It checks dangerous flaws which assure electrical equipment continuous working.
-
GDTL AC Resonant Test System for Generators
GDTL series AC Resonant Test System for Generators can be used by adjusting inductance of the reactor, or adjusting the work way of resonant frequency of the system to achieve resonance.
-
GDZJ-30S Turn-to-Turn Surge Withstand Tester
GDZJ-30S is used to test turn-to-turn insulation strength of rate voltage 10kV motor, HV and LV motor, AC/DC motor, transformer winding and coil winding.
-
VLF-Series Portable VLF Hipot Test System with Advanced Safety Features
The VLF Hipot Test System are truly compact and portable VLF test sets that determine the insulation condition of medlum voltage cables. Both test sets perform VLF and Dc testing, as well as sheath testing with sheath fault location possibilities.Its design complies with the international standard IEEE 400.2-2013.The VLF Hipot Test system combine a small and light weight VLF test set with integrated Tan Delta and Partial Discharge diagnostic modules to expand into a complete cable diagnostic system.
-
GDYD-137 AC Hipot Test Set For Insulated Boom
AC hi-pot testing is the effective and direct way to test insulation strength for electrical equipment, apparatus, or machines. It checks dangerous flaws which assure electrical equipment continuous working.
-
GDSD-140 Dielectric Strength Test Set for Insulation Sample
GDSD-140 test device is mainly suitable for making breakdown strength and withstand voltage test of solid insulating materials (such as: plastic, rubber, laminated materials, films, resins, mica, ceramics, glass, insulating paint and other insulating materials and insulating parts) under power frequency voltage or DC voltage.
-
GDTL- AC Inductance Resonance Test System for CVT
GDTL AC Resonant Test System for CVT is series resonance with power frequency specially for CVT.
-
GDTF-2700kVA/900kV AC Resonant Test System
GDTF-2700kVA/900kV is specially designed for AC withstand voltage test for 500kV or below switch, GIS, instrument transformers and neutral point of main transformers.The system includes Variable frequency power supply, exciting transformer, reactor, and capacitive voltage divider.